CEM1 / TECHNICAL NOTE · COMPANION TO DB1

CEM1: FLG in cementitious surrogates

Hydration, mechanical response and stationary transport · companion technical note to DB1

TYPE
TECHNICAL NOTE
REVISED
· v1.1
DOI
10.5281/zenodo.24280675 ↗
AUTHOR
Nikita Teslia · Fieldmind Lab

RELATED WORK / DB1

Relation to DB1

DB1 evaluated an externally proposed hypothesis: the modelled interface-organisation signal survived controls, while mechanical strengthening was not supported. CEM1 carries the matched-control approach into a separate cementitious surrogate model chain and is published as its own technical note. Open DB1 →

SUBJECT / QUESTION

What do matched controls reveal about hydration, mechanical response and stationary transport in the tested FLG cementitious surrogate?

A numerical study of FLG in two-dimensional cementitious surrogates with matched controls: the all-mode mechanical gain target was not met, and the primary stationary-transport contrast remained unresolved.

NUMERICAL EVIDENCE

Findings within the model

Findings are bounded by the tested models and controls.

StageSubjectFinding
CEM1.0–4Hydration and controlsModel-field budgets were checked; the FLG state was compared with its own FLG-free control.
CEM1.6–7Mechanical responseThe prescribed all-mode strain-energy gain target was not met in the tested domain.
CEM1.8–12Stiffness grid comparisonAt one fixed stiffness floor, the two finest grids met the effective-stiffness agreement criteria. Local energy peaks remained grid-sensitive.
CEM1.13–19Stationary transportThe primary FLG/control contrast remained unresolved; prescribed precipitation perturbations shifted the modelled transport response.

CLAIM BOUNDARY

Claim boundary

Numerical response and physical validation are separate stages.

  1. 01

    The results concern the tested two-dimensional surrogates; the final transport comparisons use one base morphology.

  2. 02

    Variational bounds enclose the effective response for frozen coefficient fields; they do not quantify material variability or model uncertainty.

  3. 03

    Physical strength, sorptivity, permeability and a qualified formulation have not been established.

  4. 04

    A diagnostic pilot protocol has been drafted for possible future evaluation. No physical pilot measurements are reported.

PUBLIC RECORD

Public technical note

CEM1: Numerical Assessment of Few-Layer Graphene in Cementitious Surrogates. Hydration, mechanical response and stationary transport · companion technical note to DB1.

The public English-language note contains model equations, schematic figures and categorical findings. Underlying numerical fields, source code and formulation specifications are retained in a restricted project archive and are not included in the public release.

CC BY-NC-ND 4.0

Open CEM1 on Zenodo ↗
FIELDSTABLE